Structural Design and Testing of a Bolted and
Gasketed Pre-Cast Concrete Segmental Lining for High External Hydrostatic
Pressure
2002
S. Swartz, H. Lum & M. McRae
Jacobs Associates, San Francisco, California
D.J. Curtis
Mott-MacDonald, London, England
J. Shamma
Metropolitan Water District, Los Angeles, California

|
|

Restrictions on water inflows into the tunnel excavations for the Inland
Feeder Arrowhead
Tunnels require the utilization of a bolted and gasketed pre-cast concrete
segmental primary lining system.
The bolted gasketed segments have been designed for a maximum expected
groundwater head of 275 meters,
in addition to other applicable loads. Each of the segment’s critical
components, including the joints, segment
body, joint edges at the gasket groove, and load-transferring packer,
are designed to assure segment performance
under the design loading conditions.
This paper discusses the load conditions
anticipated for the tunnels,
provides an overview of similar projects, discusses the design procedure
for the segments, summarizes the design
verification testing program, and discusses other important issues
that impact performance.
|